​​Committed to laboratory sample pretreatment and safety protection equipment R&D and manufacturing
  • HPLC Waste collect System
    ❤ Add to collection
  • HPLC Waste collect System

    The SE series solvent safety caps efficiently filter dust in the air to prevent contamination of the solvent which used by Chramatographic and Solid Phase Extractor instrument and ensure the accuracy of the analysis results. When the  instrument stops working, the mobile phase is prevented from volatilizing through the air inlet to protect the laboratory environment from pollution.

    • ¥0.00
      ¥0.00
      ¥0.00
      ¥0.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.00KG
    • Quantity:
    • (Inventory: 99999)
Description

The SE series solvent safety caps efficiently filter dust in the air to prevent contamination of the solvent which used by Chramatographic and Solid Phase Extractor instrument and ensure the accuracy of the analysis results. When the  instrument stops working, the mobile phase is prevented from volatilizing through the air inlet to protect the laboratory environment from pollution.


The SE series solvent safety caps efficiently filter dust in the air to prevent contamination of the solvent which used by Chramatographic and Solid Phase Extractor instrument and ensure the accuracy of the analysis results. When the  instrument stops working, the mobile phase is prevented from volatilizing through the air inlet to protect the laboratory environment from pollution.



Microporous Membrane—— Efficient Filtration
○  SE series solvent safety cap built-in PTFE microporous membrane which can efficiently filter the air so that prevent dust from contaminating the solvent and ensure the accuracy of the analysis results;


Non-Return Seal—— Prevent Volatilization
○  SE series solvent safety cap adopt high-sensitivity non-return safety valve. Once chromatographic instrument stops working, the safety valve will close and seal so that the mobile phase is prevented from volatilizing through the air inlet to protect the laboratory environment and take care of experimenter.


Time Label —— Expire Reminder
○  Press time start button on the valve once start use, the time label will record the use time in the form of a red progress bar, remind the user replace the safety valve on schedule;


Plug Installation—— Easy to Replacement
○  The safety valve on the SE series solvent safety cap is recommended to be replaced every 6 months. It adopts a quick plug installation design, which can be replaced easily by users;
Model
SE38
Profile

Bottle mouth spec
GL38 Standard bottle mouth


SE40
Profile

Bottle mouth spec
GL40 Standard bottle mouth


SE45
Profile

Bottle mouth spec
GL45 Standard bottle mouth