GREEN  SAFETY  RELIABLE  EFFICIENT
24-hour hot line:+86 189 1133 7382
sales@auwii.com
​​Committed to laboratory sample pretreatment and safety protection equipment R&D and manufacturing
  • Acid Evaporator
    ❤ Add to collection
  • Acid Evaporator

    The V series of acid blasting instrument is an excellent partner for microwave digestion equipment. The microwave digestion tube can be directly put into the acid blasting instrument for batch acid blasting. The heating body adopts isostatic graphite, and the temperature between the holes is more uniform, which fully guarantees the consistency of the acid blasting. The multiple anti-corrosion design effectively avoids the corrosion of the graphite body and the electrical system by the acid gas, and the anti-corrosion is durable.

    • ¥0.00
      ¥0.00
      ¥0.00
      ¥0.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.00KG
    • Quantity:
    • (Inventory: 99999)
Description

The V series of acid blasting instrument is an excellent partner for microwave digestion equipment. The microwave digestion tube can be directly put into the acid blasting instrument for batch acid blasting. The heating body adopts isostatic graphite, and the temperature between the holes is more uniform, which fully guarantees the consistency of the acid blasting. The multiple anti-corrosion design effectively avoids the corrosion of the graphite body and the electrical system by the acid gas, and the anti-corrosion is durable.


The V series of acid blasting instrument is an excellent partner for microwave digestion equipment. The microwave digestion tube can be directly put into the acid blasting instrument for batch acid blasting. The heating body adopts isostatic graphite, and the temperature between the holes is more uniform, which fully guarantees the consistency of the acid blasting. . The multiple anti-corrosion design effectively avoids the corrosion of the graphite body and the electrical system by the acid gas, and the anti-corrosion is durable.

main feature:

○Multiple protection, anti-corrosion and durable
The cabinet adopts stainless steel surface Teflon coating, double anti-corrosion;
Thickened Teflon coating on the surface of the graphite body effectively prevents strong acid corrosion;
Use capacitive touch buttons to isolate acid gas and avoid corrosion;
Double-layer structure design, the electrical system is located below the box body independently sealed, heat insulation and corrosion protection.

○Wireless control-safe and convenient
Built-in wifi communication module, the instrument can be controlled through mobile phone APP software;
The mobile phone APP software displays the real-time temperature curve, which can more intuitively grasp the acid rushing process;
The acid temperature and holding time can be edited and set by mobile phone;
Built-in expert library for easy use.

○Gradient heating-synchronous acid removal
Support multi-level gradient heating to avoid sample bumping;
The static pressure graphite body conducts heat more uniformly, ensuring that the temperature difference of the heating hole is better than ±1.5℃@200℃.

series
series
model  V2428
shape


width 290×deep 290×high 310  mm
Digestion hole specifications
Number of digestion holes temperature range Temperature difference between holes Heating order power(W)
diameter Φ28mm
Hole depth 155mm

24 Room temperature~210℃ ±1.5℃
(@200℃时
20 1500
model  V1243
shape


width 290×deep 290×high 310  mm
Digestion hole specifications Number of digestion holes
temperature range
Temperature difference between holes
Heating order
power(W)
diameter Φ42.5mm
Hole depth 110mm

12 Room temperature~210℃
±1.5℃
(@200℃时
20 1500
model  V1248
shape


width 290×deep 290×high 310  mm
Digestion hole specifications
Number of digestion holes
temperature range
Temperature difference between holes
Heating order
power(W)
diameter Φ47.5mm
Hole depth 115mm

12
Room temperature~210℃
±1.5℃
(@200℃时
20
1500
model  V2438
shape


width 350×deep 310×high 310  mm
Digestion hole specifications
Number of digestion holes
temperature range
Temperature difference between holes
Heating order
power(W)
diameter Φ37.5mm
Hole depth 135mm

24 Room temperature~210℃
±1.5℃
(@200℃时
20
1800
model  V4028
shape


width 350×deep 310×high 310  mm
Digestion hole specifications
Number of digestion holes
temperature range
Temperature difference between holes
Heating order
power(W)
diameter Φ28mm
Hole depth 155mm

40 Room temperature~210℃
±1.5℃
(@200℃时
20
1800
model  V2434D
shape


width 350×deep 310×high 355  mm
Digestion hole specifications
Number of digestion holes
temperature range
Temperature difference between holes
Heating order
power(W)
diameter Φ34mm
Hole depth 200mm

24 Room temperature~210℃
±1.5℃
(@200℃时
20
2000
model  V1638
shape


width 250×deep 310×high 300  mm
Digestion hole specifications
Number of digestion holes
temperature range
Temperature difference between holes
Heating order
power(W)
diameter Φ37.5mm
Hole depth 135mm

16 Room temperature~210℃
±1.5℃
(@200℃时
20
1500
model  V6428
shape


width 360×deep 420×high 350  mm
Digestion hole specifications
Number of digestion holes
temperature range
Temperature difference between holes
Heating order
power(W)
diameter Φ28mm
Hole depth 155mm

64 Room temperature~210℃
±1.5℃
(@200℃时
20
3000

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
inquiry